SIPAN 34 ANALYZER FOUR-WIRE SYSTEM, FOR PH OR ORP MEASUREMENT; PROCESS VERSION, MICROPROCESSOR-CONTROLLED WITH ILLUMINATED GRAPHIC DISPLAY, MEMBRANE KEYBOARD, TREND DISPLAY, MENU-BASED OPERATION (5 LANGUAGES), MANUAL ON CD (5 LANGUAGES), DIAGNOSTIC SOFTWAR
(2.500Gr.)
|
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR PH OR ORP MEASUREMENT; SINGLE MEASUREMENT 1 X PH OR 1 X ORP, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION, LOGBOOK, CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, MICROPROCESSOR CONTROLLED MA
(2.500Gr.)
|
SIPAN 32X ANALYZER WITH EXPLOSION PROTECTION, INTRINSIC SAFETY VERSION II 2 G EEX IA II C T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR PH OR ORP MEASUREMENT;SINGLE MEASUREMENT 1 X PH OR 1 X ORP, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION,
(2.500Gr.)
|
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR PH OR ORP MEASUREMENT; DOUBLE MEASUREMENT 2 X PH OR 2 X ORP OR 1 X PH AND 1 X ORP, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION, LOGBOOK, CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, MICROP
(2.500Gr.)
|
SIPAN 32X ANALYZER WITH EXPLOSION PROTECTION, INTRINSIC SAFETY VERSION II 2 G EEX IA II C T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR PH OR ORP MEASUREMENT;DOUBLE MEASUREMENT 2 X PH OR 1 X PH AND 1 X ORP OR 2 X ORP, MEMBRANE KEYBOARD WITH LCD,
(2.500Gr.)
|
SIPAN 32 ANALYZER WITH EXPLOSIO PROTECTION, INTRINSIC SAFETY VERSION II 2 G EEX IA II C T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR PH OR ORP MEASUREMENT; DOUBLE MEASUREMENT 2 X PH OR 2 X ORP OR 1 X PH AND 1 X ORP, MEMBRANE KEYBOARD WITH LCD, M
(2.500Gr.)
|
2EL-SENSOR FUER LEITFAEHIGKEITSMESSUNG PROZESSADAPTION: 3/4" NPT GEW. ANSCHLUSSKABEL:SEPARAT STECKBAR EINBAULAENGE: 57 MM DURCHMESSER: 16 MM ELEKTRODENMATERIAL: EDELSTAHL 1.4404 UND PES(POLYETHERSULFON) ELEKTRODENANORDNUNG:KONZENTR. THERMOMETER: PT100 INTE
(500Gr.)
|
2EL-SENSOR FUER LEITFAEHIGKEITSMESSUNG PROZESSADAPTION:3/4"NPT GEWINDE ANSCHLUSSKABEL:SEPARAT STECKBAR EINBAULAENGE: 57 MM DURCHMESSER: 16 MM ELEKTRODENMATERIAL: EDELSTAHL 1.4404 UND PES(POLYETHERSULFON) ELEKTRODENANORDNUNG:KONZENTR. THERMOMETER: PT100 INT
(500Gr.)
|
2EL-SENSOR FUER LEITFAEHIGKEITSMESSUNG PROZESSADAPTION:3/4"NPT GEWINDE ANSCHLUSSKABEL:SEPARAT STECKBAR EINBAULAENGE: 57 MM DURCHMESSER: 16 MM ELEKTRODENMATERIAL: GRAPHIT UND PES (POLYETHERSULFON) ELEKTRODENANORDNUNG:PLAN- PARALLEL, THERMOMETER: PT100 INTEG
(500Gr.)
|
DURCHLAUFGEFAESS AUS EDELSTAHL SENSORADAPTION:3/4"FNPT GEWINDE PROZESSADAPTION:1/4"FNPT GEWIND GESAMTLAENGE: 165 MM MATERIAL: EDELSTAHL 1.4404 AUSSEN-DURCHMESSER: 34 MM MAX. TEMPERATUR: 150CEL MAX. DRUCK: 25 BAR DRUCKGERAETERICHTLINIE FUER GAS 2/FLUESSIG 1
(1.500Gr.)
|
STECKER-KABEL-KOMBINATION FUR 2EL-SENSOREN KABELLAENGE: 5 M MIT STECKKOPF UND OFFENEM ENDE AUF DER ANALYZERSEITE SCHUTZART: IP 65
(700Gr.)
|
STECKER-KABEL-KOMBINATION FUR 2EL-SENSOREN KABELLAENGE: 20 M MIT STECKKOPF UND OFFENEM ENDE AUF DER ANALYZERSEITE SCHUTZART: IP 65
(700Gr.)
|
EINSCHWEISSSTUTZEN AUS EDELSTAHL 1.4404 SENSORADAPTION: 3/4 ZOLL FNPT GEWINDE GESAMTLAENGE: 30 MM AUSSENDURCHMESSER: 35 MM MAX. TEMPERATUR: 150 GRAD CEL. MAX. DRUCK: 10 BAR
(400Gr.)
|
BLINDSTOPFEN AUS EDELSTAHL 1.4401 SENSORADAPTION: 3/3 ZOLL NPT GEWINDE GESAMTLAENGE: 31 MM MAX. TEMPERATUR: 150 GR. CEL. MAX. DRUCK: 10 BAR
(300Gr.)
|
SIPAN 34 ANALYZER FOUR-WIRE SYSTEM FOR CONDUCTIVITY MEASUREMENT PROCESS VERSION, MICROPROCESSOR CONTROLLED WITH ILLUMINATED GRAPHIC DISPLAY, MEMBRANE KEYBOARD, MENU-BASED OPERATION (5 LANGUAGES), MANUAL ON CD (5 LANGUAGES), DIAGNOSTIC SOFTWARE, LOGBOOK, TE
(3.000Gr.)
|
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR CONDUCTIVITY MEASUREMENT; MEASURING PROCEDURE: TWO-ELECTRODE PROCEDURE (2EL), MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEM
(3.000Gr.)
|
SIPAN 32X ANALYZER WITH EXPLOSION PROTECTION, INTRINSIC SAFETY VERSION II 2G EEX IA IIC T4,TWO-WIRE SYSTEM FOR CONDUCTIVITY MEASUREMENT;MEASURING PROCEDURE TWO-ELECTRODE PROCEDURE (2EL), MICROPROCESSOR-CONTROLLED, MEMBRANDE KEYBOARD WITH LCD, MENU-BASED OP
(2.500Gr.)
|
4EL-SENSOR FUER LEITFAEHIGKEITSMESSUNG PROZESSADAPTION: KEGELFLANSCH DN 50 ANSCHLUSSKABEL: 5 M SEPARAT STECKBAR, EINBAULAENGE: 74MM SENSOR-DURCHMESSER: 22 MM SCHAFTMATERIAL: EPOXIDHARZ MIT GRAPHIT ELEKTRODENANORDNUNG:4 RINGELEK. THERMOMETER: PT100 INTEGRIE
(1.000Gr.)
|
4EL-SENSOR FUER LEITFAEHIGKEITSMESSUNG PROZESSADAPTION: KLEMMBAR ANSCHLUSSKABEL: 5 M FESTKABEL EINBAULAENGE: 120 MM, DURCHMESSER: 12 MM SCHAFTMATERIAL: EPOXIDHARZ MIT GRAPHIT ELEKTRODENANORDNUNG:4 RINGELEK. THERMOMETER: PT100 INTEGRIERT ZELLKONSTANTE: 0,08
(1.000Gr.)
|
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR CONDUCTIVITY MEASUREMENT; MEASURING PROCEDURE: FOUR-ELECTRODE PROCEDURE (4EL), MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TE
(3.000Gr.)
|
SIPAN 32X ANALYZER WITH EXPLOSION PROTECTION, INTRINSIC SAFETY VERSION II 2G EEX IA IIC T4,TWO-WIRE SYSTEM FOR CONDUCTIVITY MEASUREMENT;MEASURING PROCEDURE FOUR-ELECTRODE PROCEDURE (4EL), MICROPROCESSOR-CONTROLLED, MEMBRANDE KEYBOARD WITH LCD, MENU-BASED O
(2.500Gr.)
|
IND-SENSOR FUER LEITFAEHIGKEITSMESSUNG PROZESSADAPTION: KEGELFLANSCH DN 50 ANSCHLUSSKABEL:5 M FESTKABEL EINBAULAENGE: 96 MM DURCHMESSER: 41 MM SCHAFTMATERIAL: PERFLUORETHYLENPROPYLEN (FEP) THERMOMETER: PT100 INTEGRIERT ZELLKONSTANTE: 3,82 CM-1 MESSBER.: 0,
(1.000Gr.)
|
IND-SENSOR FUER LEITFAEHIGKEITSMESSUNG PROZESSADAPTION: VARIVENT 60 MM ANSCHLUSSKABEL:5 M FESTKABEL EINBAULAENGE: 40 MM SCHAFTMATERIAL: POLYETHERETHERKETON (PEEK) THERMOMETER: PT100 INTEGRIERT ZELLKONSTANTE: 3,16 CM-1 MESSBER.: 0,01 -2500 MS/CM MAX. TEMPER
(1.100Gr.)
|
IND-SENSOR FUER LEITFAEHIGKEITSMESSUNG PROZESSADAPTION: KEGELFLANSCH DN 50 ANSCHLUSSKABEL:5 M FESTKABEL EINBAULAENGE: 90 MM DURCHMESSER: 45 MM SCHAFTMATERIAL: POLYETHERETHERKETON (PEEK) THERMOMETER: PT100 INTEGRIERT ZELLKONSTANTE: 3,00 CM-1 MESSBER.: 0,01
(1.000Gr.)
|
IND-SENSOR FUER LEITFAEHIGKEITSMESSUNG FUER DEN EX-BEREICH (EEX IB IIC T4) PROZESSADAPTION: KEGELFLANSCH DN 50 ANSCHLUSSKABEL:5 M FESTKABEL EINBAULAENGE: 96 MM DURCHMESSER: 41 MM SCHAFTMATERIAL: PERFLUORETHYLENPROPYLEN (FEP) THERMOMETER: PT100 INTEGRIERT Z
(1.500Gr.)
|
ABGLEICHSET FUER INDUKTIVE LEITFAEHIGKEITSSENSOREN 7MA2200-8BA, -8CB, -8DA, -8DD, -8EA, UND -8EB
(60Gr.)
|
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR CONDUCTIVITY MEASUREMENT; MEASURING PROCEDURE: INDUCTIVE PROCEDURE (IND), MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH LCD, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEMPERA
(3.000Gr.)
|
SIPAN 32X ANALYZER WITH EXPLOSION PROTECTION, INTRINSIC SAFETY VERSION II 2G EEX IA IIC T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR CONDUCTIVITY MEASUREMENT; MEASURING PROCEDURE INDUCTIVE PROCEDURE (IND), MICROPROCESSOR-CONTROLLED, MEMBRANDE KE
(2.500Gr.)
|
SIPAN 34 ANALYZER FOUR-WIRE SYSTEM FOR MEASUREM. OF DISSOLVED OXYGEN, MICROPROC. CONTROLLED WITH ILLUMINATED GRAPHIC DISPLAY, MEMBRANE KEYBOARD, MENU-BASED OPERATION (5 LANGUAGES), DIAGNOSTIC SOFT- WARE,MANUAL ON CD (5 LANGUAGES) LOGBOOK, TEMPERATURE COMPE
(1.400Gr.)
|
SAUERSTOFF-SENSOR FUER GELOESTEN O2 IN REINSTWASSER NUR MIT SIPAN 34 ZU VERWENDEN KABEL: 5 M FESTKABEL MESSBEREICH 0.. 10 MICRO G/L BIS 0.. 1000 MICRO G/L BETRIEBSTEMP: 0 BIS 50 GRAD C DRUCKBEREICH: 1 - 10 BAR DRUCKGERAETERICHTLINIE FUER GAS 2/FLUESSIG 1 A
(1.000Gr.)
|
SAUERSTOFF-SENSOR FUER GELOESTEN O2 IM REINST- WASSER NUR MIT SIPAN 34 ZU VERWENDEN MESSBEREICH 0...10 MICRO G/L BIS 0...1000 MICRO G/L BESTEHEND AUS: O2-SENSOR MIT 5 M FESTKABEL 7MA3100-8CC DURCHLAUFARMATUR, KOMPLETT 7MA8500-8AM, MEMBRANKIT 1 7MA8500-8CC,
(2.500Gr.)
|
OXYGOLD G SAUERSTOFFELEKTRODE FUER CO2-ARME GERAENKE, REINSTWASSER, PHARMA UND CHEMIEANWENDUNGEN . STERILISIERBAR MIT 3.1B ZEUGNIS EX-KENNZEICHNUNG: II 1/2G EEX IA II C T4/T5/T6 ANSCHLUSS: PG 13,5 GEWINDE EINBAULAENGE: 120 MM DURCHMESSER: 12 MM SCHAFTMATER
(200Gr.)
|
OXYGOLD G MEMBRAN KIT FUER OXYGOLD G SAUERSTOFFSENSOR 3 MEMBRANKAPPEN . 1 PIPETTE . 2 STUECK O-RINGE (EPDM) (ELEKTROLYT 7MA3100-8HC BITTE SEPARAT BESTELLEN)
(300Gr.)
|
OXYLYTE G ELEKTROLYT FUER OXYGOLD G SAUERSTOFFSENSOR INHALT: 50 ML)
(100Gr.)
|
OXYFERM VP SAUERSTOFFELEKTRODE FUER CO2-ARME GERAENKE UND CHEMIE-INDUSTRIE . STERILISIERBAR MIT 3.1B ZEUGNIS EX-KENNZEICHNUNG: II 1/2G EEX IA II C T4/T5/T6 ANSCHLUSS: PG 13,5 GEWINDE KABEL: VP-STECKER (VP 6.0) EINBAULAENGE: 120 MM . DURCHMESSER: 12 MM SCHA
(500Gr.)
|
OXYFERM MEMBRAN KIT FUER OXYFERM VP SAUERSTOFFSENSOR 3 MEMBRANKAPPEN OXYLYTE-ELEKTROLYT 20 ML 1 PIPETTE . 3 STUECK O-RINGE (EPDM) SCHMIRGELPAPIER
(500Gr.)
|
OXYLYTE-ELEKTROLYT FUER OXYFERM SAUERSTOFFSENSOR INHALT: 50 ML
(100Gr.)
|
OXYSENS SAUERSTOFFELEKTRODE FUER WASSER UND ABWASSER ANWENDUNGEN, WARTUNGSFREI EX-KENNZEICHNUNG: II 1/2G EEX IA II C T4/T5/T6 ANSCHLUSS: PG 13,5 GEWINDE KABEL: 5 M FESTKABEL VERSIEGELT EINBAULAENGE: 120 MM DURCHMESSER: 12 MM SCHAFTMATERIAL: EDELSTAHL (1.44
(700Gr.)
|
STECKER-KABEL-KOMBINATION FUER OXYFERM VP UND OXYGOLD G SAUERSTOFFELEKTRODEN MIT VP STECKKOPF UND OFFENEM ENDE AUF DER ANALYZERSEITE KABELLAENGE: 5 M KABELDURCHMESSER: 7.5 MM
(500Gr.)
|
DURCHLAUFGEFAESS FUER SAUERSTOFFELEKTRODEN MIT EINEM SENSORANSCHLUSS ANSCHLUSS: PG 13,5 SENSORLAENGE: 120 MM WERKSTOFF: 1.4435 MAX. BETRIEBSDRUCK: 0 - 16 BAR MAX. BETRIEBSTEMPERATUR:130CEL PROZESSANSCHLUSS: . 10 MM SWAGELOCK DRUCKGERAETERICHTLINIE FUER GAS
(500Gr.)
|
POLARISATIONSMODUL G FUER OXYFERM VP UND OXYGOLD G SAUERSTOFFSENSOREN ZUR STABILISIERUNG DES SENSORS OHNE ANGESCHLOSSENEN ANALYZER
(500Gr.)
|
2EL-SENSOR MIT ZWEI GRAPHIT ELEKTRODEN ZUR LEITFAEHIGKEITS MESSUNG. . ANSCHLUSS: PG 13,5 GEWINDE KABEL: 5 M FESTKABEL VERSIEGELT EINBAULAENGE: 120 MM DURCHMESSER: 12 MM SCHAFTMATERIAL: UDEL (PSU) MESSELEKTRODEN: GRAPHIT DICHTUNG: EPDM . SCHUTZART: IP 68 .
(500Gr.)
|
KOMPENSATIONS-THERMOMETER PT100 DRUCKGERAETERICHTLINIE FUER GAS 1/FLUESSIG 1 ART. 3.3 SEP
(150Gr.)
|
ARMATUR FUER BYPASS-ANWENDUNG AUS PTFE (TEFLON)/GF25 BEFESTIGUNG DES SENSORS DURCH FLANSCH MIT DICHTUNG UND FLANSCH-VERSCHRAUBUNG DRUCKGERAETERICHTLINIE FUER GAS 1/FLUESSIG 1 ART. 3.3 SEP
(6.000Gr.)
|
VARIVENT-SPANNRING INKL. SCHRAUBEN UND MUTTERN AUS EDESTAHL W.NR 1.4404
(6.000Gr.)
|
VARIVENT-ARMATUR AUS EDELSTAHL ALS DURCHLAUFARMATUR FUER ROHRLEITUNGEN DN50, MIT 1 VERSCHLUSSSTUECK UND 2 SPANNRINGEN DRUCKGERAETERICHTLINIE FUER GAS 2/FLUESSIG 1 ART. 3.3 SEP
(1.585Gr.)
|
VERSCHLUSSRING, VARIVENT AUS EDELSTAHL 1.4404
(100Gr.)
|
VARIVENT-EINBAUARMATUR MIT ANSCHWEISS-GEWINDESTUTZEN FUER IND-LEITFAEHIGKEITSSENSOREN 7MA2200-8CD UND 7MA2200-8DD DRUCKGERAETERICHTLINIE FUER GAS 2/FLUESSIG 1 ART. 3.3 SEP
(3.600Gr.)
|
O-RING AUS EPDM FUER IND-LEITFAEHIGKEITSSENSOREN 7MA2200-8CB UND 7MA2200-8DD (VARIVENT)
(10Gr.)
|
VARIVENT SPEZIAL-DICHTUNG AUS VITON FUER IND-LEITFAEHIGKEITSSENSOREN 7MA2200-8CB UND 7MA2200-8DD
(200Gr.)
|
DURCHLAUFARMATUR KOMPLETT FUER GELOESTEN SAUERSTOFF IN REINSTWASSER DRUCKGERAETERICHTLINIE FUER GAS 1/FLUESSIG 1 ART. 3.3 SEP
(1.000Gr.)
|
DIFFERENTIAL-PH-SENSOR MIT 5 M KABEL, EINGEBAUT IN ROHRFORM- STUECK DN 50 FUER ASEPTISCHE MESSUNGEN, MIT 2 UEBERWURFMUTTERN 2 EINSCHWEISSSTUTZEN UND 2 DICHTUNGEN AUS EPDM DRUCKGERAETERICHTLINIE FUER GAS 2/FLUESSIG 1 ART. 3.3 SEP
(3.000Gr.)
|
EINSCHWEISSSTUTZEN AUS V4A FUER ASEPTISCHE MESSUNGEN, MIT UEBERWURFMUTTER. DRUCKGERAETERICHTLINIE FUER GAS 2/FLUESSIG 1 ART. 3.3 SEP
(1.050Gr.)
|
MEMBRANKIT 1 BESTEHEND AUS: 2 AUSTAUSCHMEMBRANKOEPFEN, ELKTROLYT REINIGUNGSLOESUNG UND SCHLEIFFOLIE FUER 02-SENSOR 7MA3100-8CC (REINSTWASSER)
(230Gr.)
|
DIFFERENTIAL-PH-SENSOR 7MA8500-8FM MIT STECKER-KABEL- KOMBINATION, 5M LANG, 7MA8500-8DR EINGEBAUT IN EINSCHWEISSSTUTZEN FUER ASEPTISCHE MESSUNGEN, INKLUSIV BLINDVERSCHLUSS, UEBERWURFMUTTER AUS EDELSTAHL UND DICHTUNGEN AUS EPDM DRUCKGERAETERICHTLINIE FUER G
(2.000Gr.)
|
MASTSCHELLE AUS EDELSTAHL (W.NR 1.4571) BESTEHEND AUS MONTAGEWINKEL, 2 ROHRBUEGELN UND 2 X SCHRAUBEN, SCHEIBEN UND MUTTERN
(500Gr.)
|
VARIVENT-VESCHLUSSSTUECK AUS EDELSTAHL W.NR. 1.4404
(150Gr.)
|
SPEZIALKABEL BEI SENSORUEBERWACHUNG PH, 5 M LANG
(1.000Gr.)
|
STECKER-KABEL-KOMBINATION FUER PH-EINSTABMESSKETTEN MIT INTEGRIERTEM THERMOMETER PT1000, KABELLAENGE 5 M
(240Gr.)
|
SPEZIAL STECKER-KABEL- KOMBINATION FUER EMAIL-PH- SENSOREN, BLAU, 5 M LANG
(735Gr.)
|
BLINDVERSCHLUSS AUS V4A FUER ASEPTISCHEN EINSCHWEISSSTUTZEN 7MA8500-8BY
(450Gr.)
|
PH-EINSTABMESSKETTE FUER BRAUCH- UND ABWASSER, MIT SCHRAUBSTECKKOPF PG13,5 EINBAULAGE 120MM MIT POLYMERELEKTROLYT NICHT NACHFUELLBAR KPG DIAPHRAGMA DRUCKGERAETERICHTLINIE FUER GAS 1/FLUESSIG 1 ART. 3.3 SEP
(100Gr.)
|
PH-EINSTABMESSKETTE FUER KESSELSPEISEWASSER, HOCHREINES WASSER UND BELASTETES WASSER, MIT SCHRAUBSTECKKOPF PG13,5 EINBAULAENGE 120 MM, MIT FLUESSIGKEITELEKTROLYT, NACHFUELLBAR, MIT DREIFACHKERAMIKDIAPHRAGMA DRUCKGERAETERICHTLINIE FUER GAS 1/FLUESSIG 1 ART.
(200Gr.)
|
PH-EINSTABMESSKETTE FUER BRAUCHWASSER, SUSPENSIONEN LEBENSMITTELVERARBEITUNG, ORGANISCHE LOESUNGSMITTEL, HEISSE SAEUREN UND LAUGEN, MIT SCHRAUBSTECKKOPF PG13,5 EINBAULAENGE 120 MM, WIDERSTANDSTHERMOMETER PT1000 INTEGRIERT, MIT POLYMERELEKTRO- LYT, NICHT NA
(400Gr.)
|
REDOX-EINSTABMESSKETTE FUER ORP-MESSUNG, MIT SCHRAUBSTECKKOPF PG13,5 EINBAULAENGE 120 MM, MIT PLATINRING UND DREIFACHKERAMIKDIAPHRAGMA DRUCKGERAETERICHTLINIE FUER GAS 1/FLUESSIG 1 ART. 3.3 SEP
(105Gr.)
|
WIDERSTANDSTHERMOMETER PT1000 ALLE ANWENDUNGEN, MIT MANTEL AUS GLAS, MIT SCHRAUBSTECKKOPF PG13,5 DRUCKGERAETERICHTLINIE FUER GAS 1/FLUESSIG 1 ART. 3.3 SEP
(100Gr.)
|
DIFFERENTIAL PH-SENSOR, PT100 INTEGRIERT, MIT 2 IONENSENSITIVEN EMAIL- FLAECHEN, OHNE DIAPHRAGMA, ZUM EINBAU IN ASEPTISCHEN STUTZEN
(700Gr.)
|
STECKER-KABEL-KOMBINATION FUER EINSTABMESSKETTEN, MESSELEKTRO- DEN UND BEZUGSELEKTRODEN MIT AG/AGCL-ABLEITSYSTEM UND FUER PT 1000, KABELLAENGE 10 M.
(360Gr.)
|