SIEMENS
SIEMENS Global Ürünler
|
|
|
SIEMENS Global Ürünler
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 1.6 - 16A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW CONNECTION
(180Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 1.6 - 16A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW CONNECTION
(180Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 1.6 - 16A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED CONNECTION
(180Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 1.6 - 16A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED CONNECTION
(180Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 4 - 40A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW CONNECTION
(260Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 4 - 40A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW CONNECTION
(260Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 4 - 40A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED CONNECTION
(260Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 4 - 40A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED CONNECTION
(260Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTMENT APPARENT CURRENT MONITORING 8 - 80 A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW TERMINAL
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTMENT APPARENT CURRENT MONITORING 8 - 80 A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW TERMINAL
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2, SIZE S00 BASIC, ANALOG ADJUSTMENT APPARENT CURRENT MONITORING 8 - 80 A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED TERMINAL
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2, SIZE S00 BASIC, ANALOG ADJUSTMENT APPARENT CURRENT MONITORING 8 - 80 A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED TERMINAL
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 1.6 - 16A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. OUTPUT FOR ALARM AND WARNING, MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SCREW CONNECTION
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 1.6 - 16A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR. 0-30 S BREAK AFTER FAULT 0-300 MIN SCREW CONNECTION
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 1.6 - 16A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR. 0-30 S BREAK AFTER FAULT 0-300 MIN SPRING-LOADED CONNECTION
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 1.6 - 16A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SPRING-LOADED CONNECTION
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 4 - 40A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SCREW CONNECTION
(280Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 4 - 40A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SCREW CONNECTION
(280Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 4 - 40A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SPRING-LOADED CONNECTION
(280Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 4 - 40A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SPRING-LOADED CONNECTION
(280Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S2 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 8 - 80A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SCREW CONNECTION
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S2 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 8 - 80A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SCREW CONNECTION
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S2 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 8 - 80A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SPRING-LOADED CONNECTION
(200Gr.)
|
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S2 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 8 - 80A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SPRING-LOADED CONNECTION
(200Gr.)
|
, MOUNTABLE ON CONT. 3RT2, SZ. S00, APPARENT/ACTIVE CURR. MONIT.1.6 - 16A, 20-400 HZ, 3-PH., SUPPLY 24 V DC, 1 CO CONTACT, MONITORING F. CURRENT OVER-/UNDERSHOOT, CURRENT ASYMMETRY, PHASE FAILURE / WIRE BREAK, PHASE SEQUENCE, FAULT CURRENT, BLOCKING CURRENT, SWITCHING CYCLE/OP. HOURS COUNTER, WARNING/ALARM THRESHOLDS, AUTO OR MANUAL RESET ON-DELAY 0-999.9 S OFF-DELAY 0-999.9 S RECLOSING DELAY 0-999.9MIN SCREW CONNECTION
(0Gr.)
|
, MOUNTABLE ON CONT. 3RT2, SZ. S00, APPARENT/ACTIVE CURR. MONIT. 1.6 - 16A, 20-400 HZ, 3-PH., SUPPLY 24 V DC, 1 CO CONTACT, MONITORING F. CURRENT OVER-/UNDERSHOOT, CURRENT ASYMMETRY, PHASE FAILURE / WIRE BREAK, PHASE SEQUENCE, FAULT CURRENT, BLOCKING CURRENT, SWITCHING CYCLE/OPER. HOURS COUNTER, WARNING/ALARM THRESHOLDS, AUTO OR MANUAL RESET ON-DELAY 0-999.9 S OFF-DELAY 0-999.9 S RECLOSING DELAY 0-999.9MIN SPRING-LOADED CONNECTION
(0Gr.)
|
, MOUNTABLE ON CONT. 3RT2, SZ. S0, APPARENT/ACTIVE CURR. MONIT. 4 - 40A, 20-400 HZ, 3-PH., SUPPLY 24 V DC, 1 CO CONTACT, MONITORING F. CURRENT OVER-/UNDERSHOOT, CURRENT ASYMMETRY, PHASE FAILURE / WIRE BREAK, PHASE SEQUENCE, FAULT CURRENT, BLOCKING CURRENT, SWITCHING CYCLE/OP. HOURS COUNTER, WARNING/ALARM THRESHOLDS, AUTO OR MANUAL RESET ON-DELAY 0-999.9 S OFF-DELAY 0-999.9 S RECLOSING DELAY 0-999.9MIN SCREW CONNECTION
(0Gr.)
|
, MOUNTABLE ON CONT. 3RT2, SZ. S0, APPARENT/ACTIVE CURR. MONIT. 4 - 40A, 20-400 HZ, 3-PH., SUPPLY 24 V DC, 1 CO CONTACT, MONITORING F. CURRENT OVER-/UNDERSHOOT, CURRENT ASYMMETRY, PHASE FAILURE / WIRE BREAK, PHASE SEQUENCE, FAULT CURRENT, BLOCKING CURRENT, SWITCHING CYCLE/OP. HOURS COUNTER, WARNING/ALARM THRESHOLDS, AUTO OR MANUAL RESET ON-DELAY 0-999.9 S OFF-DELAY 0-999.9 S RECLOSING DELAY 0-999.9MIN SPRING-LOADED CONNECTION
(0Gr.)
|
CURRENT MONITORING RELAY MOUNTABLE ON CONT. 3RT2, SZ. S2, APPARENT/ACTIVE CURR. MONIT. 8 - 80A, 20-400 HZ, 3-PH., SUPPLY 24 V DC, 1 CO CONTACT, MONITORING F. CURRENT OVER-/UNDERSHOOT, CURRENT ASYMMETRY, PHASE FAILURE / WIRE BREAK, PHASE SEQUENCE, FAULT CURRENT, BLOCKING CURRENT, SWITCHING CYCLE/OP. HOURS COUNTER, WARNING/ALARM THRESHOLDS, AUTO OR MANUAL RESET ON-DELAY 0-999.9 S OFF-DELAY 0-999.9 S RECLOSING DELAY 0-999.9MIN SCREW CONNECTION
(200Gr.)
|
CURRENT MONITORING RELAY MOUNTABLE ON CONT. 3RT2, SZ. S2, APPARENT/ACTIVE CURR. MONIT. 8 - 80A, 20-400 HZ, 3-PH., SUPPLY 24 V DC, 1 CO CONTACT, MONITORING F. CURRENT OVER-/UNDERSHOOT, CURRENT ASYMMETRY, PHASE FAILURE / WIRE BREAK, PHASE SEQUENCE, FAULT CURRENT, BLOCKING CURRENT, SWITCHING CYCLE/OP. HOURS COUNTER, WARNING/ALARM THRESHOLDS, AUTO OR MANUAL RESET ON-DELAY 0-999.9 S OFF-DELAY 0-999.9 S RECLOSING DELAY 0-999.9MIN SPRING-LOADED CONNECTION
(200Gr.)
|
SEALABLE COVER FOR DIRECTLY ATTACHABLE CURRENT MONITORING RELAYS 3RR2 TO PROTECT AGAINST UNAUTHORIZED CONFIGURING
(1Gr.)
|
|